Patient with a diagnosis of autoimmune hemolytic anemia. 🩸 Complete Blood Count (Sysmex XT-2000i): WBC — 79.6 × 10⁹/L (ref. 4.0–9.0) RBC — 2.91 × 10¹²/L (ref. 3.80–5.70) HGB — 87 g/L (ref. 117–173) MCV — 95.2 fL (ref. 80–103) MCH — 29.9 pg (ref. 27–35) PLT — 73 × 10⁹/L (ref. 150–400) Reticulocytes:
- relative count: 18.8 % (ref. 0.5–1.5)
- absolute count: 547.1 × 10⁹/L (ref. 24.0–84.0)
Differential leukocyte count: left shift to myelocytes. Normoblasts — 189 per 100 leukocytes.
Note: Automatic leukocyte and differential leukocyte count on the Sysmex XT-2000i analyzer is difficult due to the presence of a large number of nucleated red blood cells (normoblasts), which leads to an overestimation of the WBC level. After adjustment for normoblasts, the true leukocyte count is 27.5 × 10⁹/L.
🙏 Clinical case kindly provided by Vera Kirnas Biologist, Clinical Diagnostic Laboratory, F.S. Ankudinov Yuzhno-Sakhalinsk City Hospital